RF312GLYCOL WiFi Glycol Simulant Data Logger

$318.91 USD

RF312GLYCOL

The RF312Glycol Diligence WiFi Glycol Simulant Data Logger is a battery powered device with an internal rechargeable lithium polymer battery, but can be permanently powered using an RF320 USB power supply (available separately).

The LCD display includes several features including Max and Min readings and indicators for low battery, alarms, WiFi connection and signal strength. The RF312 has a protection rating of IP43 and the glycol probe, IP67. The RF312 is freestanding, but can be attached to a wall or surface using the bracket provided. The glycol buffer probe is supplied with a detachable magnetic base for easy installation.

During configuration, the data logger will search for an existing wireless network while physically connected to the PC. It can then be placed anywhere within range of the network. If the data logger temporarily loses connectivity with the network, it will log readings until it is able to communicate again with the PC application or the Cloud (max 30 days at 10 second sample interval). Although the WiFi data loggers have an impressive range this can be increased by using WiFi extenders.

17025 compliant certification is available.

The data logger is IEEE 802.11b/g/n compliant, supports WEP, WPA/WPA2 encryption and enterprise networks*.

*MS-CHAPv2, PEAP, EAP-FAST, EAP-TTLS

Features

  • High Accuracy Glycol Buffer Probe Temperature Measurement range -40 to +125°C / -40 to +257°F
  • Wirelessly stream and view data on the Comark Cloud or on a PC
  • Data logger set up is easy using our free PC software
  • View and analyze multiple data loggers, including graphing of historic data
  • Configurable high and low alarms with indicator
  • Data logger memory stores data even if WiFi is temporarily disconnected

WiFi


The Diligence WiFi Data Logger now features ‘BGN’ (IEEE 802.11b/g/n) WiFi compatibility.  One of the major benefits of the switch to type ‘BGN’ WiFi is that it speeds network communications. IT departments in many schools and hospitals have been turning off ‘B’ compatibility to improve network speeds, so ‘BGN’ devices are often all that they will consider for new network devices.

RF300 loggers now have a new two-Line LCD and a new LCD surround. The new segment battery indicator shows the charge on the battery all the time.

  • Temperature Measurement Range: -40 to +125°C / -40 to +257°F
  • Plug & Play Installation using existing WiFi Network
  • Supplied with High Accuracy Glycol Buffer Probe

 

Probe

 

The RFAXGLYCOL Glycol Buffer Probe is designed for use in monitoring the temperature of vaccines and is designed to act as a replacement part for the Buffer Probe that is supplied as part of the RF312Vaccine Diligence WiFi Glycol Simulant Data Logger.

  • Temperature Measurement Range: -40°C to +100°C / -40°F to +212°F
  • Glycol Buffer Response Time: 40 Minutes to achieve 90% of temperature change
  • Glycol Buffer probe Lead length: 3 Meters

 

Specifications

 

 

Sensor Type High Accuracy ‘PLUS’ Specification Thermistor
Battery Life >6* Months
USB Supply Voltage 4.5 to 5.5 Vdc
Operating Temperature Range -20°C to +60°C / -4°F to +140°F
Logging Period (User Configurable) 10 Seconds to 12 Hours (Typical 10 Minutes)
Transmission Period (User Configurable) 1 minute to 24 hours (Typical 1 Hour)
Temperature Measurement Range -40 to +125°C / -40°F to +257°F
Temperature Measurement Resolution 0.01°C / 0.01°F
Temperature Display Resolution 0.01°C / 0.01°F
System Temperature Accuracy (-15 to +80°C) ±0.2°C
System Temperature Accuracy (+5°F and +176°F) ±0.4°F
System Temperature Accuracy (-40 to +125°C) ±0.6°C
System Temperature Accuracy (-40°F to +257°F) ±1°F
Logger Dimensions Height 82mm / 3.23" x Width 70mm / 2.75" x Depth 22mm / 0.86"
Supplied Glycol Buffer Probe Lead Length 3m
WiFi Compliance IEEE 802.11b/g/n compliant, supports WEP, WPA/WPA2 encryption and enterprise networks (MS-CHAPv2, PEAP, EAP-FAST, EAP-TTLS)
Glycol Buffer Response Time (t90*) 40 minutes
*The t90 response is the time taken for the temperature probe to achieve 90% of the ambient temperature, after being subjected to an instant change. This response time is designed to reproduce the thermal characteristics of a vaccine vial, accurately tracking the temperature of the vaccine.

 

Shipping & Delivery

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

Terms And Conditions

Making A Purchase

Making a purchase could not be easier. Just browse our store and add any items that you wish to buy into the shopping cart. After you have finished your selections, click on 'Checkout' and you will be asked for a few details that we need to be able to complete the order.


We accept credit cards and PayPal for payment. If you are shopping from outside of the USA, place your order and your credit card company will convert the transaction to your own currency. Please note that we can not ship to all international locations. If we are unable to ship to your location, we will advise you and your credit card will not be charged.

We accept Discover, Visa, Master Card and American Express. We do not charge for any item until it is ready to ship. Back-ordered items are not charged until they are shipped. You may send your credit card information via phone, fax, snail mail or securely over the Internet.

When confirmation of order is received, this is to indicate that we have received your order. It does not indicate that a contract exists between us. We will indicate acceptance of your order, and hence a contract between us, when we send you an invoice. We have included this term to protect us in the case that a mistake has been made in pricing, we have inadvertently underpriced goods, or we are no longer able to supply a particular product for some reason. In the case of a change of price, we will always contact you first to ensure that the price is acceptable.
 Credit Card Security
 When you place your order with us, your credit card number is encrypted for transmission to us using 128 bit encryption. Your credit card details are never by us since they are transmitted directly to the processing company.  As such, all refunds must be made to the same card used for the purchase.

Contacting Us
If you need to reach us, please email us using the link on the store page, alternatively, you can reach us at:

Tech Instrumentation Inc.
750 E Kiowa Ave.
PO Box 2029
Elizabeth, CO 80107-2029
USA

Phone: [800) 390-0004 Toll free
Phone: (303) 841-7567
Fax: (303) 840-8568

NOTE: We do not accept unsolicited advertisements at the facsimile number.


Email: info@techinstrument.com

Shipping And Handling
Shipping and handling charges are shown on a page just prior to your placing the order. We can ship to many parts of the world that are not allowed on the site. Please e-mail us for a shipping quote. Please call if you have any questions. 
PLEASE NOTE: If you return an item that you ordered with free shipping, we may, at our option deduct our shipping cost from your refund.

Delivery Schedule
We will normally ship your order to you within 1 to 3 business days. We will notify you via e-mail or telephone if we will be unable to ship within 3 business days. If your order is urgent, please let us know. We'll do our best to expedite urgent orders.
Back Orders
If your item is not in stock and we will not be able to ship within 10 business days, we will back order for you. You will always be emailed with the option to cancel your order if you would rather not wait.
Tax Charges
Orders made from within Colorado - sales tax will be applied. We do not currently charge taxes outside of Colorado, but some of our payment processors may charge sales tax and remit it directly to your state.
Guarantee
Most of our products come with a one year warranty. Most of the Cooper-Atkins thermometers which carry a five-year warranty. Most probes come with a one year warranty. Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.
Privacy Policy
Tech Instrumentation will not disclose buyers' information to third parties other than when order details are processed as part of the order fulfillment.  Cookies are used on this shopping site to keep track of the contents of your shopping cart, to store delivery addresses if the address book is used and to store your details if you select the 'Remember Me' Option. They are also used after you have logged on as part of that process. You can turn off cookies within your browser by going to 'Tools | Internet Options | Privacy' and selecting to block cookies. If you turn off cookies, you will be unable to place orders or benefit from the other features that use cookies.

Returns Policy
Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.  Most items come with a minimum one year warranty against defects in manufacturing.

CLAIMS FOR SHORTAGES OR ITEMS DAMAGED IN TRANSIT MUST BE SUBMITTED TO US WITHIN 3 DAYS OF RECEIPT OF THE PRODUCT. IF DAMAGE IS NOTED UPON DELIVERY, PLEASE NOTIFY CARRIER IMMEDIATELY AND BE SURE TO KEEP THE SHIPPING CONTAINER AND ALL PACKING MATERIAL. NO CLAIMS FOR SHORTAGES OR CARRIER DAMAGE WILL BE HONORED BEYOND 3 DAYS AFTER DELIVERY.

New and unopened items sold by Tech Instrumentation.com may be returned within 30 days of delivery. All items require prior authorization from Tech Instrumentation before they can be returned. We will also pay the return shipping costs if the return is a result of our error (e.g. you received an incorrect or defective item). New and unopened items being returned due to a customer error in ordering or handling will be subject to a restocking fee of 30% and must be returned freight prepaid.

All returns require a RGA number from Tech Instrumentation prior to being returned. Items must be returned postage paid to our facility in order to be considered for refund. Please call 303 841-7567 to obtain a RGA number if you need to return an item. Non defective returns must be in the original unopened packaging with all accessories to be eligible for a refund. Unopened items are subject to a 20% inspection and restocking charge. Non defective items that have been opened or are missing any parts including instructions are not eligible for return. Defective items will be repaired or replaced per mfg. policy. Shipping & Handling charges are not refundable. Service charges (repairs, certifications etc.) and special order items are never refundable. Non defective items must be returned within 30 days of the date we shipped to you in order to be eligible for refund. We pay shipping back you your location for all warranty returns. Items that have been damaged due to misuse or abuse, as judged by Tech Instrumentation are never eligible for a refund.

Refused/Undeliverable shipments: We will refund a minimum 75% of the cost of the product less shipping costs (both ways) for shipments that are returned to us as refused or undeliverable. Service charges (repairs, certifications etc.) are warranted but never refundable. Purchaser agrees to pay all charge-back and related costs incurred by us in the event a credit card charge-back is initiated by the purchaser for refused shipments. Please contact us directly and we will refund per our policies.  Shipping and handling charges are not refundable except in the event of an error on our part.

by Comark
Type: Data Loggers

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
John F. (Tijuana, MX)

RF312GLYCOL

The RF312Glycol Diligence WiFi Glycol Simulant Data Logger is a battery powered device with an internal rechargeable lithium polymer battery, but can be permanently powered using an RF320 USB power supply (available separately).

The LCD display includes several features including Max and Min readings and indicators for low battery, alarms, WiFi connection and signal strength. The RF312 has a protection rating of IP43 and the glycol probe, IP67. The RF312 is freestanding, but can be attached to a wall or surface using the bracket provided. The glycol buffer probe is supplied with a detachable magnetic base for easy installation.

During configuration, the data logger will search for an existing wireless network while physically connected to the PC. It can then be placed anywhere within range of the network. If the data logger temporarily loses connectivity with the network, it will log readings until it is able to communicate again with the PC application or the Cloud (max 30 days at 10 second sample interval). Although the WiFi data loggers have an impressive range this can be increased by using WiFi extenders.

17025 compliant certification is available.

The data logger is IEEE 802.11b/g/n compliant, supports WEP, WPA/WPA2 encryption and enterprise networks*.

*MS-CHAPv2, PEAP, EAP-FAST, EAP-TTLS

  • High Accuracy Glycol Buffer Probe Temperature Measurement range -40 to +125°C / -40 to +257°F
  • Wirelessly stream and view data on the Comark Cloud or on a PC
  • Data logger set up is easy using our free PC software
  • View and analyze multiple data loggers, including graphing of historic data
  • Configurable high and low alarms with indicator
  • Data logger memory stores data even if WiFi is temporarily disconnected

The Diligence WiFi Data Logger now features ‘BGN’ (IEEE 802.11b/g/n) WiFi compatibility.  One of the major benefits of the switch to type ‘BGN’ WiFi is that it speeds network communications. IT departments in many schools and hospitals have been turning off ‘B’ compatibility to improve network speeds, so ‘BGN’ devices are often all that they will consider for new network devices.

RF300 loggers now have a new two-Line LCD and a new LCD surround. The new segment battery indicator shows the charge on the battery all the time.

  • Temperature Measurement Range: -40 to +125°C / -40 to +257°F
  • Plug & Play Installation using existing WiFi Network
  • Supplied with High Accuracy Glycol Buffer Probe

 

 

The RFAXGLYCOL Glycol Buffer Probe is designed for use in monitoring the temperature of vaccines and is designed to act as a replacement part for the Buffer Probe that is supplied as part of the RF312Vaccine Diligence WiFi Glycol Simulant Data Logger.

  • Temperature Measurement Range: -40°C to +100°C / -40°F to +212°F
  • Glycol Buffer Response Time: 40 Minutes to achieve 90% of temperature change
  • Glycol Buffer probe Lead length: 3 Meters

 

 

 

Sensor Type High Accuracy ‘PLUS’ Specification Thermistor
Battery Life >6* Months
USB Supply Voltage 4.5 to 5.5 Vdc
Operating Temperature Range -20°C to +60°C / -4°F to +140°F
Logging Period (User Configurable) 10 Seconds to 12 Hours (Typical 10 Minutes)
Transmission Period (User Configurable) 1 minute to 24 hours (Typical 1 Hour)
Temperature Measurement Range -40 to +125°C / -40°F to +257°F
Temperature Measurement Resolution 0.01°C / 0.01°F
Temperature Display Resolution 0.01°C / 0.01°F
System Temperature Accuracy (-15 to +80°C) ±0.2°C
System Temperature Accuracy (+5°F and +176°F) ±0.4°F
System Temperature Accuracy (-40 to +125°C) ±0.6°C
System Temperature Accuracy (-40°F to +257°F) ±1°F
Logger Dimensions Height 82mm / 3.23" x Width 70mm / 2.75" x Depth 22mm / 0.86"
Supplied Glycol Buffer Probe Lead Length 3m
WiFi Compliance IEEE 802.11b/g/n compliant, supports WEP, WPA/WPA2 encryption and enterprise networks (MS-CHAPv2, PEAP, EAP-FAST, EAP-TTLS)
Glycol Buffer Response Time (t90*) 40 minutes
*The t90 response is the time taken for the temperature probe to achieve 90% of the ambient temperature, after being subjected to an instant change. This response time is designed to reproduce the thermal characteristics of a vaccine vial, accurately tracking the temperature of the vaccine.