USRIC-4  SINGLE-USE USB TEMPERATURE LOGGER

The LogTag USRIC-4 is a temperature data logger that is commonly used in various applications to monitor and record temperature readings. Some of the applications where the LogTag USRIC-4 may be useful include:

Pharmaceutical storage and transportation - The LogTag USRIC-4 can be used to monitor the temperature of drugs during storage and transportation to ensure that they are stored under the correct temperature conditions.

Food storage and transportation - The LogTag USRIC-4 can be used to monitor the temperature of food during storage and transportation to ensure that it is stored under the correct temperature conditions and prevent spoilage.

Medical storage - The LogTag USRIC-4 can be used to monitor the temperature of medical supplies, such as vaccines, to ensure that they are stored at the correct temperature and prevent spoilage.

Laboratory research - The LogTag USRIC-4 can be used to monitor the temperature of samples during research experiments to ensure that the samples are maintained at the required temperature conditions.

HVAC monitoring - The LogTag USRIC-4 can be used to monitor the temperature in HVAC systems to ensure that they are operating correctly and efficiently.

Temperature monitoring in manufacturing - The LogTag USRIC-4 can be used to monitor the temperature of manufacturing processes to ensure that they are operating under the correct temperature conditions.


Its small size, ease of use, and accurate temperature readings make it a valuable tool in various industries where temperature monitoring is critical.


Specifications

  • Sensor Measurement Range -30°C to +60°C (-22°F to +140°F).
  • Operating Temperature Range -30°C to +60°C (-22°F to +140°F).*
  • Storage Temperature Range 0°C to +40°C (32°F to +104°F).
  • Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -5°C to +30°C (23°F to +86°F).
  • ±0.8°C (±1.5°F) or better for measurements in other areas of rated range.
  • Actual performance is typically much better than the rated values.
  • Accuracy figures can be improved by recalibration.
  • Rated Temperature Reading Resolution Less than 0.1°C/F.
  • LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
  • Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s).
  • Recording Capacity 3937 temperature readings. 14 days @ 5min logging, 41 days @ 15min logging.
  • Sampling Interval Configurable from 1 minute to 18 hours.
  • Logging Start Options Push button start or specific date & time.
  • Alarms 1 configurable upper and 1 configurable lower alarms.
  • Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
  • Download Time Typically less than 4 seconds for full memory (3937 readings), depending on computer or readout device used.
  • Environmental IP64 with USB cap fitted.
  • Power Source CR2032 3V LiMnO2 Battery (Fixed).
  • Battery Life 2 years storage, followed by 6 months normal use.
  • Real Time Clock Built-in real time clock.
  • Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
  • Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
  • Connection Interface USB 2.0, A-type plug
  • Software LogTag® Analyzer 2.5 or higher, PDF Generator
  • Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
  • Weight 30g.
  • Case Material Polycarbonate.
  • Footnote *(-30°C to +60 °C applies to Loggers with serial numbers 5x34x33580 or greater. Loggers with serial numbers prior to this have an operating temperature range of -25°C to +60°C).

    Shipping & Delivery

    We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

    Terms And Conditions

    Making A Purchase

    Making a purchase could not be easier. Just browse our store and add any items that you wish to buy into the shopping cart. After you have finished your selections, click on 'Checkout' and you will be asked for a few details that we need to be able to complete the order.


    We accept credit cards and PayPal for payment. If you are shopping from outside of the USA, place your order and your credit card company will convert the transaction to your own currency. Please note that we can not ship to all international locations. If we are unable to ship to your location, we will advise you and your credit card will not be charged.

    We accept Discover, Visa, Master Card and American Express. We do not charge for any item until it is ready to ship. Back-ordered items are not charged until they are shipped. You may send your credit card information via phone, fax, snail mail or securely over the Internet.

    When confirmation of order is received, this is to indicate that we have received your order. It does not indicate that a contract exists between us. We will indicate acceptance of your order, and hence a contract between us, when we send you an invoice. We have included this term to protect us in the case that a mistake has been made in pricing, we have inadvertently underpriced goods, or we are no longer able to supply a particular product for some reason. In the case of a change of price, we will always contact you first to ensure that the price is acceptable.
     Credit Card Security
     When you place your order with us, your credit card number is encrypted for transmission to us using 128 bit encryption. Your credit card details are never by us since they are transmitted directly to the processing company.  As such, all refunds must be made to the same card used for the purchase.

    Contacting Us
    If you need to reach us, please email us using the link on the store page, alternatively, you can reach us at:

    Tech Instrumentation Inc.
    750 E Kiowa Ave.
    PO Box 2029
    Elizabeth, CO 80107-2029
    USA

    Phone: [800) 390-0004 Toll free
    Phone: (303) 841-7567
    Fax: (303) 840-8568

    NOTE: We do not accept unsolicited advertisements at the facsimile number.


    Email: info@techinstrument.com

    Shipping And Handling
    Shipping and handling charges are shown on a page just prior to your placing the order. We can ship to many parts of the world that are not allowed on the site. Please e-mail us for a shipping quote. Please call if you have any questions. 
    PLEASE NOTE: If you return an item that you ordered with free shipping, we may, at our option deduct our shipping cost from your refund.

    Delivery Schedule
    We will normally ship your order to you within 1 to 3 business days. We will notify you via e-mail or telephone if we will be unable to ship within 3 business days. If your order is urgent, please let us know. We'll do our best to expedite urgent orders.
    Back Orders
    If your item is not in stock and we will not be able to ship within 10 business days, we will back order for you. You will always be emailed with the option to cancel your order if you would rather not wait.
    Tax Charges
    Orders made from within Colorado - sales tax will be applied. We do not currently charge taxes outside of Colorado, but some of our payment processors may charge sales tax and remit it directly to your state.
    Guarantee
    Most of our products come with a one year warranty. Most of the Cooper-Atkins thermometers which carry a five-year warranty. Most probes come with a one year warranty. Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.
    Privacy Policy
    Tech Instrumentation will not disclose buyers' information to third parties other than when order details are processed as part of the order fulfillment.  Cookies are used on this shopping site to keep track of the contents of your shopping cart, to store delivery addresses if the address book is used and to store your details if you select the 'Remember Me' Option. They are also used after you have logged on as part of that process. You can turn off cookies within your browser by going to 'Tools | Internet Options | Privacy' and selecting to block cookies. If you turn off cookies, you will be unable to place orders or benefit from the other features that use cookies.

    Returns Policy
    Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.  Most items come with a minimum one year warranty against defects in manufacturing.

    CLAIMS FOR SHORTAGES OR ITEMS DAMAGED IN TRANSIT MUST BE SUBMITTED TO US WITHIN 3 DAYS OF RECEIPT OF THE PRODUCT. IF DAMAGE IS NOTED UPON DELIVERY, PLEASE NOTIFY CARRIER IMMEDIATELY AND BE SURE TO KEEP THE SHIPPING CONTAINER AND ALL PACKING MATERIAL. NO CLAIMS FOR SHORTAGES OR CARRIER DAMAGE WILL BE HONORED BEYOND 3 DAYS AFTER DELIVERY.

    New and unopened items sold by Tech Instrumentation.com may be returned within 30 days of delivery. All items require prior authorization from Tech Instrumentation before they can be returned. We will also pay the return shipping costs if the return is a result of our error (e.g. you received an incorrect or defective item). New and unopened items being returned due to a customer error in ordering or handling will be subject to a restocking fee of 30% and must be returned freight prepaid.

    All returns require a RGA number from Tech Instrumentation prior to being returned. Items must be returned postage paid to our facility in order to be considered for refund. Please call 303 841-7567 to obtain a RGA number if you need to return an item. Non defective returns must be in the original unopened packaging with all accessories to be eligible for a refund. Unopened items are subject to a 20% inspection and restocking charge. Non defective items that have been opened or are missing any parts including instructions are not eligible for return. Defective items will be repaired or replaced per mfg. policy. Shipping & Handling charges are not refundable. Service charges (repairs, certifications etc.) and special order items are never refundable. Non defective items must be returned within 30 days of the date we shipped to you in order to be eligible for refund. We pay shipping back you your location for all warranty returns. Items that have been damaged due to misuse or abuse, as judged by Tech Instrumentation are never eligible for a refund.

    Refused/Undeliverable shipments: We will refund a minimum 75% of the cost of the product less shipping costs (both ways) for shipments that are returned to us as refused or undeliverable. Service charges (repairs, certifications etc.) are warranted but never refundable. Purchaser agrees to pay all charge-back and related costs incurred by us in the event a credit card charge-back is initiated by the purchaser for refused shipments. Please contact us directly and we will refund per our policies.  Shipping and handling charges are not refundable except in the event of an error on our part.

    by LogTag
    Type: Data Loggers

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    The LogTag USRIC-4 is a temperature data logger that is commonly used in various applications to monitor and record temperature readings. Some of the applications where the LogTag USRIC-4 may be useful include:

    Pharmaceutical storage and transportation - The LogTag USRIC-4 can be used to monitor the temperature of drugs during storage and transportation to ensure that they are stored under the correct temperature conditions.

    Food storage and transportation - The LogTag USRIC-4 can be used to monitor the temperature of food during storage and transportation to ensure that it is stored under the correct temperature conditions and prevent spoilage.

    Medical storage - The LogTag USRIC-4 can be used to monitor the temperature of medical supplies, such as vaccines, to ensure that they are stored at the correct temperature and prevent spoilage.

    Laboratory research - The LogTag USRIC-4 can be used to monitor the temperature of samples during research experiments to ensure that the samples are maintained at the required temperature conditions.

    HVAC monitoring - The LogTag USRIC-4 can be used to monitor the temperature in HVAC systems to ensure that they are operating correctly and efficiently.

    Temperature monitoring in manufacturing - The LogTag USRIC-4 can be used to monitor the temperature of manufacturing processes to ensure that they are operating under the correct temperature conditions.


    Its small size, ease of use, and accurate temperature readings make it a valuable tool in various industries where temperature monitoring is critical.


    • Sensor Measurement Range -30°C to +60°C (-22°F to +140°F).
    • Operating Temperature Range -30°C to +60°C (-22°F to +140°F).*
    • Storage Temperature Range 0°C to +40°C (32°F to +104°F).
    • Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -5°C to +30°C (23°F to +86°F).
    • ±0.8°C (±1.5°F) or better for measurements in other areas of rated range.
    • Actual performance is typically much better than the rated values.
    • Accuracy figures can be improved by recalibration.
    • Rated Temperature Reading Resolution Less than 0.1°C/F.
    • LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
    • Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s).
    • Recording Capacity 3937 temperature readings. 14 days @ 5min logging, 41 days @ 15min logging.
    • Sampling Interval Configurable from 1 minute to 18 hours.
    • Logging Start Options Push button start or specific date & time.
    • Alarms 1 configurable upper and 1 configurable lower alarms.
    • Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
    • Download Time Typically less than 4 seconds for full memory (3937 readings), depending on computer or readout device used.
    • Environmental IP64 with USB cap fitted.
    • Power Source CR2032 3V LiMnO2 Battery (Fixed).
    • Battery Life 2 years storage, followed by 6 months normal use.
    • Real Time Clock Built-in real time clock.
    • Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
    • Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
    • Connection Interface USB 2.0, A-type plug
    • Software LogTag® Analyzer 2.5 or higher, PDF Generator
    • Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
    • Weight 30g.
    • Case Material Polycarbonate.
    • Footnote *(-30°C to +60 °C applies to Loggers with serial numbers 5x34x33580 or greater. Loggers with serial numbers prior to this have an operating temperature range of -25°C to +60°C).