N2014 Thermocouple Temperature Data Logger

$183.34 USD

N2014 

N2014 Temperature Data Logger

The Comark N2014 temperature data logger is a compact and portable device that is designed to monitor and record temperature readings in a wide range of environments, including food service, pharmaceutical, and laboratory settings.

The data logger is designed to be used with up to 3 type-K thermocouple probes, which allows for accurate temperature measurements in a range of -328 to 2372 degrees Fahrenheit (-200 to 1300 degrees Celsius). It has a large, easy-to-read digital display that shows the current temperature reading, as well as minimum and maximum temperature readings.

The Comark N2014 data logger is capable of storing up to 16,000 temperature readings, which can be downloaded to a computer for analysis and record-keeping. The data logger is also equipped with an alarm function, which can be set to alert users when temperature readings fall outside of a specified range.

The device is compact and lightweight, making it easy to handle and transport. It is also designed to be durable and resistant to water and dust, with a rugged construction that can withstand harsh environments.

The Comark N2014 temperature data logger is a reliable and versatile tool for monitoring and recording temperature readings in a wide range of settings, including many industrial, food service, pharmaceutical, and laboratory applications.


Diligence EV temperature and humidity data loggers feature compact, durable, lightweight design for use in many applications including the food, pharmaceutical and chemical industries and the monitoring of medicines and other sensitive materials in transit or storage. The loggers are also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems, and countless other applications.

Requires 3 Probe Thermocouple Adapter Cable (N2000ADP/K) for use with multiple probes or standard thermocouple connectors.
Thermocouple probes can be used in a wide variety of applications and have a variety of options allowing you to choose a temperature probe that works best for you!


REQUIRED OPTIONS


N2000ADP/K if using with standard Thermocouple probes or if using with multiple probes
N2000CRU - One required per computer you are using with the N2014 regardless of the number of loggers being used.
Probe(s)


Features

  • Four total channels with up to 3 external thermocouple probes
  • Connect up to 3 external type K Thermocouple probes via the N2000ADP/K adapter cable (included) 
  • Audible & visual alarm indications 
  • LCD display for temperature readings and alarm indication 
  • Wide measurement range from -200 °C to +1372 °C (type K) 
  • Tough, molded cases, dust and waterproof to IP67 standards 
  • Large memory capacity of up to 16000 readings 
  • Ability to log over multiple periods 
  • Compatibility with the versatile and proven Evolution Windows software
  • Single, multi-function button 
  • LED indicators to show active logging and alarm conditions, plus audible alarm warning 
  • Long battery life of up to 5 years 
  • Two year warranty 
  • Requires N2000 Interface Cradle with EVSW Software (See option 1. One required per PC regardless of the number of N2014 loggers you purchase.)



Specifications

  • Sensor Type Thermocouple Type T
  • Thermocouple type K
  • Thermistor
  • Measurement Range 
  • Type K -200 °C to +1372 °C/-328 °F to +2502 °F
  • Type T -200 °C to +400 °C/-328 °F to +752 °F
  • Thermistor -40 °C to +70 °C/-40 °F to +158 °F
  • Scales °C and °F
  • Resolution (Thermocouple) 0.2 °C up to and including +300 °C
  • 0.5 °C above +300 °C
  • Accuracy at +20 °C, ambient ±0.5 °C +0.3% of reading
  • Accuracy at -20 °C to +40 °C, ambient ±0.5 °C +0.5% of reading
  • Accuracy at -40 °C to +70 °C, ambient ±1.0 °C +1.0% of reading
  • Accuracy at -20 °C to +40 °C ±0.3 °C Thermistor
  • Accuracy at -40 °C to +70 °C ±0.5 °C Thermistor
  • Memory 32K 
  • 1 channel 16000 samples
  • 2 channels 8000 samples
  • 3 channels 5300 samples
  • 4 channels 4000 samples
  • Communications Via infra red interface
  • Download Time 3 minutes for 10,000 readings (typical)
  • Logging Frequency Programmable between 1 second and 99 hours
  • Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
  • Ambient Storage -40 °C to +70 °C/-40 °F to +158 °F
  • Logging Start Programmable date and time or manual start from instrument multi-function button
  • Software Windows based software for N2014 
  • Battery Type 1 x AA size 3.6V replaceable lithium battery
  • Battery Life Up to 5 years
  • Case Material ABS
  • Environmental Protection IP67 BS EN 60529 IEC 529
  • LED Indication 
  • Red Alarm
  • Green Logger Active
  • Dimensions 
  • Length 88mm/3.5ins (including fixing lug)
  • Width 80mm/3.1ins
  • Depth 35mm/1.4ins
Shipping & Delivery

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

Terms And Conditions

Making A Purchase

Making a purchase could not be easier. Just browse our store and add any items that you wish to buy into the shopping cart. After you have finished your selections, click on 'Checkout' and you will be asked for a few details that we need to be able to complete the order.


We accept credit cards and PayPal for payment. If you are shopping from outside of the USA, place your order and your credit card company will convert the transaction to your own currency. Please note that we can not ship to all international locations. If we are unable to ship to your location, we will advise you and your credit card will not be charged.

We accept Discover, Visa, Master Card and American Express. We do not charge for any item until it is ready to ship. Back-ordered items are not charged until they are shipped. You may send your credit card information via phone, fax, snail mail or securely over the Internet.

When confirmation of order is received, this is to indicate that we have received your order. It does not indicate that a contract exists between us. We will indicate acceptance of your order, and hence a contract between us, when we send you an invoice. We have included this term to protect us in the case that a mistake has been made in pricing, we have inadvertently underpriced goods, or we are no longer able to supply a particular product for some reason. In the case of a change of price, we will always contact you first to ensure that the price is acceptable.
 Credit Card Security
 When you place your order with us, your credit card number is encrypted for transmission to us using 128 bit encryption. Your credit card details are never by us since they are transmitted directly to the processing company.  As such, all refunds must be made to the same card used for the purchase.

Contacting Us
If you need to reach us, please email us using the link on the store page, alternatively, you can reach us at:

Tech Instrumentation Inc.
750 E Kiowa Ave.
PO Box 2029
Elizabeth, CO 80107-2029
USA

Phone: [800) 390-0004 Toll free
Phone: (303) 841-7567
Fax: (303) 840-8568

NOTE: We do not accept unsolicited advertisements at the facsimile number.


Email: info@techinstrument.com

Shipping And Handling
Shipping and handling charges are shown on a page just prior to your placing the order. We can ship to many parts of the world that are not allowed on the site. Please e-mail us for a shipping quote. Please call if you have any questions. 
PLEASE NOTE: If you return an item that you ordered with free shipping, we may, at our option deduct our shipping cost from your refund.

Delivery Schedule
We will normally ship your order to you within 1 to 3 business days. We will notify you via e-mail or telephone if we will be unable to ship within 3 business days. If your order is urgent, please let us know. We'll do our best to expedite urgent orders.
Back Orders
If your item is not in stock and we will not be able to ship within 10 business days, we will back order for you. You will always be emailed with the option to cancel your order if you would rather not wait.
Tax Charges
Orders made from within Colorado - sales tax will be applied. We do not currently charge taxes outside of Colorado, but some of our payment processors may charge sales tax and remit it directly to your state.
Guarantee
Most of our products come with a one year warranty. Most of the Cooper-Atkins thermometers which carry a five-year warranty. Most probes come with a one year warranty. Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.
Privacy Policy
Tech Instrumentation will not disclose buyers' information to third parties other than when order details are processed as part of the order fulfillment.  Cookies are used on this shopping site to keep track of the contents of your shopping cart, to store delivery addresses if the address book is used and to store your details if you select the 'Remember Me' Option. They are also used after you have logged on as part of that process. You can turn off cookies within your browser by going to 'Tools | Internet Options | Privacy' and selecting to block cookies. If you turn off cookies, you will be unable to place orders or benefit from the other features that use cookies.

Returns Policy
Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.  Most items come with a minimum one year warranty against defects in manufacturing.

CLAIMS FOR SHORTAGES OR ITEMS DAMAGED IN TRANSIT MUST BE SUBMITTED TO US WITHIN 3 DAYS OF RECEIPT OF THE PRODUCT. IF DAMAGE IS NOTED UPON DELIVERY, PLEASE NOTIFY CARRIER IMMEDIATELY AND BE SURE TO KEEP THE SHIPPING CONTAINER AND ALL PACKING MATERIAL. NO CLAIMS FOR SHORTAGES OR CARRIER DAMAGE WILL BE HONORED BEYOND 3 DAYS AFTER DELIVERY.

New and unopened items sold by Tech Instrumentation.com may be returned within 30 days of delivery. All items require prior authorization from Tech Instrumentation before they can be returned. We will also pay the return shipping costs if the return is a result of our error (e.g. you received an incorrect or defective item). New and unopened items being returned due to a customer error in ordering or handling will be subject to a restocking fee of 30% and must be returned freight prepaid.

All returns require a RGA number from Tech Instrumentation prior to being returned. Items must be returned postage paid to our facility in order to be considered for refund. Please call 303 841-7567 to obtain a RGA number if you need to return an item. Non defective returns must be in the original unopened packaging with all accessories to be eligible for a refund. Unopened items are subject to a 20% inspection and restocking charge. Non defective items that have been opened or are missing any parts including instructions are not eligible for return. Defective items will be repaired or replaced per mfg. policy. Shipping & Handling charges are not refundable. Service charges (repairs, certifications etc.) and special order items are never refundable. Non defective items must be returned within 30 days of the date we shipped to you in order to be eligible for refund. We pay shipping back you your location for all warranty returns. Items that have been damaged due to misuse or abuse, as judged by Tech Instrumentation are never eligible for a refund.

Refused/Undeliverable shipments: We will refund a minimum 75% of the cost of the product less shipping costs (both ways) for shipments that are returned to us as refused or undeliverable. Service charges (repairs, certifications etc.) are warranted but never refundable. Purchaser agrees to pay all charge-back and related costs incurred by us in the event a credit card charge-back is initiated by the purchaser for refused shipments. Please contact us directly and we will refund per our policies.  Shipping and handling charges are not refundable except in the event of an error on our part.

by Comark
Type: Data Loggers

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

N2014 Temperature Data Logger

The Comark N2014 temperature data logger is a compact and portable device that is designed to monitor and record temperature readings in a wide range of environments, including food service, pharmaceutical, and laboratory settings.

The data logger is designed to be used with up to 3 type-K thermocouple probes, which allows for accurate temperature measurements in a range of -328 to 2372 degrees Fahrenheit (-200 to 1300 degrees Celsius). It has a large, easy-to-read digital display that shows the current temperature reading, as well as minimum and maximum temperature readings.

The Comark N2014 data logger is capable of storing up to 16,000 temperature readings, which can be downloaded to a computer for analysis and record-keeping. The data logger is also equipped with an alarm function, which can be set to alert users when temperature readings fall outside of a specified range.

The device is compact and lightweight, making it easy to handle and transport. It is also designed to be durable and resistant to water and dust, with a rugged construction that can withstand harsh environments.

The Comark N2014 temperature data logger is a reliable and versatile tool for monitoring and recording temperature readings in a wide range of settings, including many industrial, food service, pharmaceutical, and laboratory applications.


Diligence EV temperature and humidity data loggers feature compact, durable, lightweight design for use in many applications including the food, pharmaceutical and chemical industries and the monitoring of medicines and other sensitive materials in transit or storage. The loggers are also ideal for building services, scientific experiments, production processes and heating, ventilating and air conditioning systems, and countless other applications.

Requires 3 Probe Thermocouple Adapter Cable (N2000ADP/K) for use with multiple probes or standard thermocouple connectors.
Thermocouple probes can be used in a wide variety of applications and have a variety of options allowing you to choose a temperature probe that works best for you!


N2000ADP/K if using with standard Thermocouple probes or if using with multiple probes
N2000CRU - One required per computer you are using with the N2014 regardless of the number of loggers being used.
Probe(s)

  • Four total channels with up to 3 external thermocouple probes
  • Connect up to 3 external type K Thermocouple probes via the N2000ADP/K adapter cable (included) 
  • Audible & visual alarm indications 
  • LCD display for temperature readings and alarm indication 
  • Wide measurement range from -200 °C to +1372 °C (type K) 
  • Tough, molded cases, dust and waterproof to IP67 standards 
  • Large memory capacity of up to 16000 readings 
  • Ability to log over multiple periods 
  • Compatibility with the versatile and proven Evolution Windows software
  • Single, multi-function button 
  • LED indicators to show active logging and alarm conditions, plus audible alarm warning 
  • Long battery life of up to 5 years 
  • Two year warranty 
  • Requires N2000 Interface Cradle with EVSW Software (See option 1. One required per PC regardless of the number of N2014 loggers you purchase.)
  • Sensor Type Thermocouple Type T
  • Thermocouple type K
  • Thermistor
  • Measurement Range 
  • Type K -200 °C to +1372 °C/-328 °F to +2502 °F
  • Type T -200 °C to +400 °C/-328 °F to +752 °F
  • Thermistor -40 °C to +70 °C/-40 °F to +158 °F
  • Scales °C and °F
  • Resolution (Thermocouple) 0.2 °C up to and including +300 °C
  • 0.5 °C above +300 °C
  • Accuracy at +20 °C, ambient ±0.5 °C +0.3% of reading
  • Accuracy at -20 °C to +40 °C, ambient ±0.5 °C +0.5% of reading
  • Accuracy at -40 °C to +70 °C, ambient ±1.0 °C +1.0% of reading
  • Accuracy at -20 °C to +40 °C ±0.3 °C Thermistor
  • Accuracy at -40 °C to +70 °C ±0.5 °C Thermistor
  • Memory 32K 
  • 1 channel 16000 samples
  • 2 channels 8000 samples
  • 3 channels 5300 samples
  • 4 channels 4000 samples
  • Communications Via infra red interface
  • Download Time 3 minutes for 10,000 readings (typical)
  • Logging Frequency Programmable between 1 second and 99 hours
  • Internal Sensor Response time T90 = 15 to 30 minutes in ambient air
  • Ambient Storage -40 °C to +70 °C/-40 °F to +158 °F
  • Logging Start Programmable date and time or manual start from instrument multi-function button
  • Software Windows based software for N2014 
  • Battery Type 1 x AA size 3.6V replaceable lithium battery
  • Battery Life Up to 5 years
  • Case Material ABS
  • Environmental Protection IP67 BS EN 60529 IEC 529
  • LED Indication 
  • Red Alarm
  • Green Logger Active
  • Dimensions 
  • Length 88mm/3.5ins (including fixing lug)
  • Width 80mm/3.1ins
  • Depth 35mm/1.4ins