RTR-505-maL Current Data Logger (4-20mA)

$231.40 USD

NOTE:  If you choose an item with the Large Battery Pack, the large battery is NOT included.  We do sell them HERE.  Also, if you choose this option, YOUR ORDER MUST SHIP via GROUND ONLY.  

 

The RTR-505-TC, 505-Pt, 505-V, 505-mA, and 505-P* are wireless Communication data loggers designed to measure and record temperature (Thermocouple/Pt), voltage, 4-20mA, or pulse.

The RTR-500GSM (one of our Communication Interfaces for the RTR-500 Series) is currently compatible with RTR-501, RTR-502, RTR-503, RTR-505-TC and RTR-505-Pt.

Select the Wireless Data Logger to Suit Your Needs:

RTR-501: Internal Temperature Sensor
Internal sensor provides optimum waterproof and dust proof capabilities. This is the perfect Data Logger for use in harsh environments.

RTR-502: External Temperature Sensor for Wide Measurement Range
It includes model TR-5106 sensor but many others are available as options.

RTR-503 / 507: External Temperature and Humidity Sensor
While both models come with a sensor for temperature and humidity measurement, a high precision temperature/humidity sensor for RTR-507 extends the measurement range and accuracy.
The body is splash proof (IP64 rated for use in daily life) and can be used in wet environments. (Note: The sensor is not water resistant; avoid dew condensation and dampness.)

RTR-505: Wireless Data Logger with Input Module
The RTR-505 can measure and record different measurement items:

RTR-505-TC: Temperature Measurement using a Thermocouple Sensor
RTR-505-Pt: Temperature Measurement using a Pt100 or Pt1000 Sensor
RTR-505-V: Voltage Measurement using a variety of Sensors
RTR-505-mA: 4-20mA Measurement using a variety of Sensors
RTR-505-P: Pulse Measurement using a variety of Sensors


RTR-574 / 574-H: For Luminescence, UV Intensity, Temperature and Humidity Measurement. It includes two sensors to measure and record Luminescence/UV (ISA-3151) and temperature/humidity (THA-3151). The RTR-574-H includes our high precision temperature/humidity sensor (HHA-3151) and the Luminescence/UV sensor (ISA-3151).

RTR-576 / 576-H: For CO2 Concentration, Temperature and Humidity Measurement
The RTR-576 includes an internal CO2 sensor and an external temperature/humidity sensor. The RTR-576-H has the same CO2 sensor, but comes with a high precision temperature/humidity sensor for a wider measurement range: -30 to 80¡C and 0 to 99%RH. The rated accuracy for CO2 measurements is up to 5,000 ppm and the display range is up to 9,999 ppm.

The Data Loggers in our RTR-500 Series only function as Remote Units. Base Units are required to carry out wireless communication.
RTR-500 Series Loggers cannot be used with RTR-57U, RTR-50 or RTR-5W.
The sensor included with RTR-503/507 is not water resistant.
The sensor connector of the Input Module that is included with RTR-505 is not water resistant.</ul></ul>


Neither the RTR-574/576 Unit nor the included sensor are water resistant.

Large Logging Capacity: Up to 16,000 Readings
RTR-501/502/505: Maximum of 16,000 readings
16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-501, RTR-502, or RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.

RTR-503/507: Maximum of 8,000 data sets
One data set consists of readings for Temperature and Humidity measurements. A Base Unit can download via wireless communication one RTR-503 Remote Unit at full logging capacity (8,000 data sets) in about four minutes.

RTR-574/576: Maximum of 8,000 data sets

The RTR-574 has one data set consisting of readings for all four channels: Luminescence, UV intensity, temperature and humidity.
The RTR-576 has one data set consisting of readings for all three channels: CO2 concentration, temperature and humidity.

* By using the software supplied with a Base Unit, the recording interval for a Remote Unit can be set to one of fifteen recording intervals (1 second to 60 minutes).
Low Energy Consumption Design

RTR-501/502/503/505/507
The RTR-500 Series Data Loggers use one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months.
Model names which include "L" are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.

The RTR-574 uses one AA alkaline battery. If one Unit of full data is downloaded once a day via wireless communication, the estimated battery life will be about four months. (There are no L-types models of RTR-574/576.) Measurement with a Variety of Sensors

RTR-505
The RTR-505 allows for a variety of commercially available sensors to be connected to the included Input Module.
This new flexibility has widened the range of possible applications without having to change Base Units.
RTR-574 and RTR-576 featuring Button Operation


Shipping & Delivery

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

Terms And Conditions

Making A Purchase

Making a purchase could not be easier. Just browse our store and add any items that you wish to buy into the shopping cart. After you have finished your selections, click on 'Checkout' and you will be asked for a few details that we need to be able to complete the order.


We accept credit cards and PayPal for payment. If you are shopping from outside of the USA, place your order and your credit card company will convert the transaction to your own currency. Please note that we can not ship to all international locations. If we are unable to ship to your location, we will advise you and your credit card will not be charged.

We accept Discover, Visa, Master Card and American Express. We do not charge for any item until it is ready to ship. Back-ordered items are not charged until they are shipped. You may send your credit card information via phone, fax, snail mail or securely over the Internet.

When confirmation of order is received, this is to indicate that we have received your order. It does not indicate that a contract exists between us. We will indicate acceptance of your order, and hence a contract between us, when we send you an invoice. We have included this term to protect us in the case that a mistake has been made in pricing, we have inadvertently underpriced goods, or we are no longer able to supply a particular product for some reason. In the case of a change of price, we will always contact you first to ensure that the price is acceptable.
 Credit Card Security
 When you place your order with us, your credit card number is encrypted for transmission to us using 128 bit encryption. Your credit card details are never by us since they are transmitted directly to the processing company.  As such, all refunds must be made to the same card used for the purchase.

Contacting Us
If you need to reach us, please email us using the link on the store page, alternatively, you can reach us at:

Tech Instrumentation Inc.
750 E Kiowa Ave.
PO Box 2029
Elizabeth, CO 80107-2029
USA

Phone: [800) 390-0004 Toll free
Phone: (303) 841-7567
Fax: (303) 840-8568

NOTE: We do not accept unsolicited advertisements at the facsimile number.


Email: info@techinstrument.com

Shipping And Handling
Shipping and handling charges are shown on a page just prior to your placing the order. We can ship to many parts of the world that are not allowed on the site. Please e-mail us for a shipping quote. Please call if you have any questions. 
PLEASE NOTE: If you return an item that you ordered with free shipping, we may, at our option deduct our shipping cost from your refund.

Delivery Schedule
We will normally ship your order to you within 1 to 3 business days. We will notify you via e-mail or telephone if we will be unable to ship within 3 business days. If your order is urgent, please let us know. We'll do our best to expedite urgent orders.
Back Orders
If your item is not in stock and we will not be able to ship within 10 business days, we will back order for you. You will always be emailed with the option to cancel your order if you would rather not wait.
Tax Charges
Orders made from within Colorado - sales tax will be applied. We do not currently charge taxes outside of Colorado, but some of our payment processors may charge sales tax and remit it directly to your state.
Guarantee
Most of our products come with a one year warranty. Most of the Cooper-Atkins thermometers which carry a five-year warranty. Most probes come with a one year warranty. Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.
Privacy Policy
Tech Instrumentation will not disclose buyers' information to third parties other than when order details are processed as part of the order fulfillment.  Cookies are used on this shopping site to keep track of the contents of your shopping cart, to store delivery addresses if the address book is used and to store your details if you select the 'Remember Me' Option. They are also used after you have logged on as part of that process. You can turn off cookies within your browser by going to 'Tools | Internet Options | Privacy' and selecting to block cookies. If you turn off cookies, you will be unable to place orders or benefit from the other features that use cookies.

Returns Policy
Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.  Most items come with a minimum one year warranty against defects in manufacturing.

CLAIMS FOR SHORTAGES OR ITEMS DAMAGED IN TRANSIT MUST BE SUBMITTED TO US WITHIN 3 DAYS OF RECEIPT OF THE PRODUCT. IF DAMAGE IS NOTED UPON DELIVERY, PLEASE NOTIFY CARRIER IMMEDIATELY AND BE SURE TO KEEP THE SHIPPING CONTAINER AND ALL PACKING MATERIAL. NO CLAIMS FOR SHORTAGES OR CARRIER DAMAGE WILL BE HONORED BEYOND 3 DAYS AFTER DELIVERY.

New and unopened items sold by Tech Instrumentation.com may be returned within 30 days of delivery. All items require prior authorization from Tech Instrumentation before they can be returned. We will also pay the return shipping costs if the return is a result of our error (e.g. you received an incorrect or defective item). New and unopened items being returned due to a customer error in ordering or handling will be subject to a restocking fee of 30% and must be returned freight prepaid.

All returns require a RGA number from Tech Instrumentation prior to being returned. Items must be returned postage paid to our facility in order to be considered for refund. Please call 303 841-7567 to obtain a RGA number if you need to return an item. Non defective returns must be in the original unopened packaging with all accessories to be eligible for a refund. Unopened items are subject to a 20% inspection and restocking charge. Non defective items that have been opened or are missing any parts including instructions are not eligible for return. Defective items will be repaired or replaced per mfg. policy. Shipping & Handling charges are not refundable. Service charges (repairs, certifications etc.) and special order items are never refundable. Non defective items must be returned within 30 days of the date we shipped to you in order to be eligible for refund. We pay shipping back you your location for all warranty returns. Items that have been damaged due to misuse or abuse, as judged by Tech Instrumentation are never eligible for a refund.

Refused/Undeliverable shipments: We will refund a minimum 75% of the cost of the product less shipping costs (both ways) for shipments that are returned to us as refused or undeliverable. Service charges (repairs, certifications etc.) are warranted but never refundable. Purchaser agrees to pay all charge-back and related costs incurred by us in the event a credit card charge-back is initiated by the purchaser for refused shipments. Please contact us directly and we will refund per our policies.  Shipping and handling charges are not refundable except in the event of an error on our part.

by TandD
Type: Data Loggers

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

NOTE:  If you choose an item with the Large Battery Pack, the large battery is NOT included.  We do sell them HERE.  Also, if you choose this option, YOUR ORDER MUST SHIP via GROUND ONLY.  

 

The RTR-505-TC, 505-Pt, 505-V, 505-mA, and 505-P* are wireless Communication data loggers designed to measure and record temperature (Thermocouple/Pt), voltage, 4-20mA, or pulse.

The RTR-500GSM (one of our Communication Interfaces for the RTR-500 Series) is currently compatible with RTR-501, RTR-502, RTR-503, RTR-505-TC and RTR-505-Pt.

Select the Wireless Data Logger to Suit Your Needs:

RTR-501: Internal Temperature Sensor
Internal sensor provides optimum waterproof and dust proof capabilities. This is the perfect Data Logger for use in harsh environments.

RTR-502: External Temperature Sensor for Wide Measurement Range
It includes model TR-5106 sensor but many others are available as options.

RTR-503 / 507: External Temperature and Humidity Sensor
While both models come with a sensor for temperature and humidity measurement, a high precision temperature/humidity sensor for RTR-507 extends the measurement range and accuracy.
The body is splash proof (IP64 rated for use in daily life) and can be used in wet environments. (Note: The sensor is not water resistant; avoid dew condensation and dampness.)

RTR-505: Wireless Data Logger with Input Module
The RTR-505 can measure and record different measurement items:

RTR-505-TC: Temperature Measurement using a Thermocouple Sensor
RTR-505-Pt: Temperature Measurement using a Pt100 or Pt1000 Sensor
RTR-505-V: Voltage Measurement using a variety of Sensors
RTR-505-mA: 4-20mA Measurement using a variety of Sensors
RTR-505-P: Pulse Measurement using a variety of Sensors


RTR-574 / 574-H: For Luminescence, UV Intensity, Temperature and Humidity Measurement. It includes two sensors to measure and record Luminescence/UV (ISA-3151) and temperature/humidity (THA-3151). The RTR-574-H includes our high precision temperature/humidity sensor (HHA-3151) and the Luminescence/UV sensor (ISA-3151).

RTR-576 / 576-H: For CO2 Concentration, Temperature and Humidity Measurement
The RTR-576 includes an internal CO2 sensor and an external temperature/humidity sensor. The RTR-576-H has the same CO2 sensor, but comes with a high precision temperature/humidity sensor for a wider measurement range: -30 to 80¡C and 0 to 99%RH. The rated accuracy for CO2 measurements is up to 5,000 ppm and the display range is up to 9,999 ppm.

The Data Loggers in our RTR-500 Series only function as Remote Units. Base Units are required to carry out wireless communication.
RTR-500 Series Loggers cannot be used with RTR-57U, RTR-50 or RTR-5W.
The sensor included with RTR-503/507 is not water resistant.
The sensor connector of the Input Module that is included with RTR-505 is not water resistant.</ul></ul>


Neither the RTR-574/576 Unit nor the included sensor are water resistant.

Large Logging Capacity: Up to 16,000 Readings
RTR-501/502/505: Maximum of 16,000 readings
16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-501, RTR-502, or RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.

RTR-503/507: Maximum of 8,000 data sets
One data set consists of readings for Temperature and Humidity measurements. A Base Unit can download via wireless communication one RTR-503 Remote Unit at full logging capacity (8,000 data sets) in about four minutes.

RTR-574/576: Maximum of 8,000 data sets

The RTR-574 has one data set consisting of readings for all four channels: Luminescence, UV intensity, temperature and humidity.
The RTR-576 has one data set consisting of readings for all three channels: CO2 concentration, temperature and humidity.

* By using the software supplied with a Base Unit, the recording interval for a Remote Unit can be set to one of fifteen recording intervals (1 second to 60 minutes).
Low Energy Consumption Design

RTR-501/502/503/505/507
The RTR-500 Series Data Loggers use one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months.
Model names which include "L" are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.

The RTR-574 uses one AA alkaline battery. If one Unit of full data is downloaded once a day via wireless communication, the estimated battery life will be about four months. (There are no L-types models of RTR-574/576.) Measurement with a Variety of Sensors

RTR-505
The RTR-505 allows for a variety of commercially available sensors to be connected to the included Input Module.
This new flexibility has widened the range of possible applications without having to change Base Units.
RTR-574 and RTR-576 featuring Button Operation