Environmental Monitor

$1,607.00 USD
Add Data Logging Option:

Environmental Monitor - Item #ELSEC765 is backordered and will ship as soon as it is back in stock.

Special Order Item: Typically ships in 1-2 weeks.

This single environmental instrument measures the four parameters that cause most damage to buildings, valuable objects, documents, etc: ultraviolet and visible light, humidity and temperature.

The 765 measures and displays visible light (Lux or Foot-candles), UV light (mW/M² or µW/lumen), temperature (°C or °F) and humidity (%RH). This is the world standard instrument for museums, art galleries conservators or any application requiring a controlled environment.

The 765C (with data logging) is the same as 765 with data logging capacity for over 70,000 readings of all 4 parameters. No special software is required, logged information is stored on an internal USB Flash disc and the data can be downloaded onto a PC and viewed with any spreadsheet (Excel etc). A free application (RView) is also available for download that displays the data as a zoomable graph that can be saved as an image for inclusion in documents and/or printed.

For many years it has been recognized that one of the major causes of damage to museum objects and other antiquities is the fading and rotting effect of light on the object. The most damaging part of the illumination is its ultraviolet (UV) content.

Since 1976 Littlemore Scientific (ELSEC) has been providing instruments that enable the conservator to measure the UV content of light and thereby protect valuable exhibits. Using the 765, measurements can be taken of the proportion of UV present (mW/lumen), the total amount of UV (mW/M²), the amount of visible light present as Lux or Foot-candles. Temperature can be measured in °C or °F, humidity is shown as % Relative Humidity (%RH) and dew point. The displayed units can easily be changed by the user.

Min/max values and their time of measurement are displayed for each parameter.

Anyone can take measurements straight out of the box with little, if any, reference to the instruction manual. The appropriate button is pushed depending on the measurement required and the reading is taken. The unit automatically turns off 10 seconds after the last reading unless a button is held down for over 5 seconds, this causes continuous measurements to be taken until another button is pressed. The large 8 line display enables an easy to use menu system to select the more advanced functions, change units etc.

Units of measurement for UV

Traditionally UV has been measured in museums as the proportion of ultraviolet present. This result is useful for checking a particular lamp or window because the proportion of UV does not change with the distance from the light source. Using a simple rule, the amount of UV on an object can be limited (it is usual to arrange that the proportion of UV should not exceed 75mW/lumen in museums). The actual amount of damage done is determined by the total amount of UV falling on the object, so it is useful to be able to measure this directly, especially if non standard amounts of illumination are required. The amount of UV should be as little as possible but in general should not exceed 20mW/M².

A Lux readout is provided to control illumination and limit damage done by visible light. Normal museum light levels should be limited to 150-250 Lux.

Dimensions: 5.9" x 2.5" x 1" (150 x 65 x 25 mm) including RH/Temperature probe
Weight: 5.6 oz (165 g) with batteries.

Specifications

Visible Wavelength Range: 400 to 700 nM (CIE response). No correction required for different light sources.
Visible Power Range: 0.1 to 200,000 Lux (0.1 to 20,000 Foot-candles)
UV Wavelength Range: 300 to 400 nm
UV Power Range: 2 to 50,000 mW / sqm
UV Proportion Range: 8 to 10,000 mW / Lumen
RH Sensor: Capacitive film type
RH Range: 0 to 100% RH
Display Resolution: Lux: 0.1 up to 100 then 1
Foot-candles: 0.1 up to 100 then 1
UV: 0.1 up to 100 then 1
Proportion of UV: 1 mW / Lumen
Temperature: 0.1°C or °F
RH: 0.1
Accuracy: Light and UV: 5% ± 1 displayed digit
Temperature: ±0.5°C (±0.9°F)
RH: ±2.5%
Angular Response:
(Light & UV)
Cosine
Readout: 8 line graphical Liquid Crystal Display with automatic backlight
Data Logging Time Intervals:
(Time Till Full)
10 seconds (30 hours), 1 minute (7½ days), 10 minutes (75 days), 1 hour (454 days)
Data Logging Storage Capacity: 10,900 readings of all 4 parameters
Storage Resolution for Logged Data: Light & UV: 0.1% of saved value
Temperature: 0.5°C
Humidity: 0.5% RH
Computer Interface: IrDA compatible wireless infrared link.
Date Function: Display as day-month-year or month-day-year.
Batteries: 2 alkaline AA type
Battery Life: Approx. 100 hours continuous use or 12,000 readings taking 30 seconds each. Battery life will be less if the display backlight is used
External Power Supply:
Unless specifically requested, the meter does NOT include a connection for an external supply.
4.0 to 5.2V DC, 100 mA A suitable mains power supply can be provided as an optional extra (please specify mains voltage required).
Operating Temperature: 32 to 122°F
0 to 50°C

 

Comparison Chart



Shipping & Delivery

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

Terms And Conditions

Making A Purchase

Making a purchase could not be easier. Just browse our store and add any items that you wish to buy into the shopping cart. After you have finished your selections, click on 'Checkout' and you will be asked for a few details that we need to be able to complete the order.


We accept credit cards and PayPal for payment. If you are shopping from outside of the USA, place your order and your credit card company will convert the transaction to your own currency. Please note that we can not ship to all international locations. If we are unable to ship to your location, we will advise you and your credit card will not be charged.

We accept Discover, Visa, Master Card and American Express. We do not charge for any item until it is ready to ship. Back-ordered items are not charged until they are shipped. You may send your credit card information via phone, fax, snail mail or securely over the Internet.

When confirmation of order is received, this is to indicate that we have received your order. It does not indicate that a contract exists between us. We will indicate acceptance of your order, and hence a contract between us, when we send you an invoice. We have included this term to protect us in the case that a mistake has been made in pricing, we have inadvertently underpriced goods, or we are no longer able to supply a particular product for some reason. In the case of a change of price, we will always contact you first to ensure that the price is acceptable.
 Credit Card Security
 When you place your order with us, your credit card number is encrypted for transmission to us using 128 bit encryption. Your credit card details are never by us since they are transmitted directly to the processing company.  As such, all refunds must be made to the same card used for the purchase.

Contacting Us
If you need to reach us, please email us using the link on the store page, alternatively, you can reach us at:

Tech Instrumentation Inc.
750 E Kiowa Ave.
PO Box 2029
Elizabeth, CO 80107-2029
USA

Phone: [800) 390-0004 Toll free
Phone: (303) 841-7567
Fax: (303) 840-8568

NOTE: We do not accept unsolicited advertisements at the facsimile number.


Email: info@techinstrument.com

Shipping And Handling
Shipping and handling charges are shown on a page just prior to your placing the order. We can ship to many parts of the world that are not allowed on the site. Please e-mail us for a shipping quote. Please call if you have any questions. 
PLEASE NOTE: If you return an item that you ordered with free shipping, we may, at our option deduct our shipping cost from your refund.

Delivery Schedule
We will normally ship your order to you within 1 to 3 business days. We will notify you via e-mail or telephone if we will be unable to ship within 3 business days. If your order is urgent, please let us know. We'll do our best to expedite urgent orders.
Back Orders
If your item is not in stock and we will not be able to ship within 10 business days, we will back order for you. You will always be emailed with the option to cancel your order if you would rather not wait.
Tax Charges
Orders made from within Colorado - sales tax will be applied. We do not currently charge taxes outside of Colorado, but some of our payment processors may charge sales tax and remit it directly to your state.
Guarantee
Most of our products come with a one year warranty. Most of the Cooper-Atkins thermometers which carry a five-year warranty. Most probes come with a one year warranty. Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.
Privacy Policy
Tech Instrumentation will not disclose buyers' information to third parties other than when order details are processed as part of the order fulfillment.  Cookies are used on this shopping site to keep track of the contents of your shopping cart, to store delivery addresses if the address book is used and to store your details if you select the 'Remember Me' Option. They are also used after you have logged on as part of that process. You can turn off cookies within your browser by going to 'Tools | Internet Options | Privacy' and selecting to block cookies. If you turn off cookies, you will be unable to place orders or benefit from the other features that use cookies.

Returns Policy
Buyer assumes full responsibility in determining the suitability of these items for buyers intended use.  Most items come with a minimum one year warranty against defects in manufacturing.

CLAIMS FOR SHORTAGES OR ITEMS DAMAGED IN TRANSIT MUST BE SUBMITTED TO US WITHIN 3 DAYS OF RECEIPT OF THE PRODUCT. IF DAMAGE IS NOTED UPON DELIVERY, PLEASE NOTIFY CARRIER IMMEDIATELY AND BE SURE TO KEEP THE SHIPPING CONTAINER AND ALL PACKING MATERIAL. NO CLAIMS FOR SHORTAGES OR CARRIER DAMAGE WILL BE HONORED BEYOND 3 DAYS AFTER DELIVERY.

New and unopened items sold by Tech Instrumentation.com may be returned within 30 days of delivery. All items require prior authorization from Tech Instrumentation before they can be returned. We will also pay the return shipping costs if the return is a result of our error (e.g. you received an incorrect or defective item). New and unopened items being returned due to a customer error in ordering or handling will be subject to a restocking fee of 30% and must be returned freight prepaid.

All returns require a RGA number from Tech Instrumentation prior to being returned. Items must be returned postage paid to our facility in order to be considered for refund. Please call 303 841-7567 to obtain a RGA number if you need to return an item. Non defective returns must be in the original unopened packaging with all accessories to be eligible for a refund. Unopened items are subject to a 20% inspection and restocking charge. Non defective items that have been opened or are missing any parts including instructions are not eligible for return. Defective items will be repaired or replaced per mfg. policy. Shipping & Handling charges are not refundable. Service charges (repairs, certifications etc.) and special order items are never refundable. Non defective items must be returned within 30 days of the date we shipped to you in order to be eligible for refund. We pay shipping back you your location for all warranty returns. Items that have been damaged due to misuse or abuse, as judged by Tech Instrumentation are never eligible for a refund.

Refused/Undeliverable shipments: We will refund a minimum 75% of the cost of the product less shipping costs (both ways) for shipments that are returned to us as refused or undeliverable. Service charges (repairs, certifications etc.) are warranted but never refundable. Purchaser agrees to pay all charge-back and related costs incurred by us in the event a credit card charge-back is initiated by the purchaser for refused shipments. Please contact us directly and we will refund per our policies.  Shipping and handling charges are not refundable except in the event of an error on our part.

Type: Light Meters

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Special Order Item: Typically ships in 1-2 weeks.

This single environmental instrument measures the four parameters that cause most damage to buildings, valuable objects, documents, etc: ultraviolet and visible light, humidity and temperature.

The 765 measures and displays visible light (Lux or Foot-candles), UV light (mW/M² or µW/lumen), temperature (°C or °F) and humidity (%RH). This is the world standard instrument for museums, art galleries conservators or any application requiring a controlled environment.

The 765C (with data logging) is the same as 765 with data logging capacity for over 70,000 readings of all 4 parameters. No special software is required, logged information is stored on an internal USB Flash disc and the data can be downloaded onto a PC and viewed with any spreadsheet (Excel etc). A free application (RView) is also available for download that displays the data as a zoomable graph that can be saved as an image for inclusion in documents and/or printed.

For many years it has been recognized that one of the major causes of damage to museum objects and other antiquities is the fading and rotting effect of light on the object. The most damaging part of the illumination is its ultraviolet (UV) content.

Since 1976 Littlemore Scientific (ELSEC) has been providing instruments that enable the conservator to measure the UV content of light and thereby protect valuable exhibits. Using the 765, measurements can be taken of the proportion of UV present (mW/lumen), the total amount of UV (mW/M²), the amount of visible light present as Lux or Foot-candles. Temperature can be measured in °C or °F, humidity is shown as % Relative Humidity (%RH) and dew point. The displayed units can easily be changed by the user.

Min/max values and their time of measurement are displayed for each parameter.

Anyone can take measurements straight out of the box with little, if any, reference to the instruction manual. The appropriate button is pushed depending on the measurement required and the reading is taken. The unit automatically turns off 10 seconds after the last reading unless a button is held down for over 5 seconds, this causes continuous measurements to be taken until another button is pressed. The large 8 line display enables an easy to use menu system to select the more advanced functions, change units etc.

Units of measurement for UV

Traditionally UV has been measured in museums as the proportion of ultraviolet present. This result is useful for checking a particular lamp or window because the proportion of UV does not change with the distance from the light source. Using a simple rule, the amount of UV on an object can be limited (it is usual to arrange that the proportion of UV should not exceed 75mW/lumen in museums). The actual amount of damage done is determined by the total amount of UV falling on the object, so it is useful to be able to measure this directly, especially if non standard amounts of illumination are required. The amount of UV should be as little as possible but in general should not exceed 20mW/M².

A Lux readout is provided to control illumination and limit damage done by visible light. Normal museum light levels should be limited to 150-250 Lux.

Dimensions: 5.9" x 2.5" x 1" (150 x 65 x 25 mm) including RH/Temperature probe
Weight: 5.6 oz (165 g) with batteries.

Visible Wavelength Range: 400 to 700 nM (CIE response). No correction required for different light sources.
Visible Power Range: 0.1 to 200,000 Lux (0.1 to 20,000 Foot-candles)
UV Wavelength Range: 300 to 400 nm
UV Power Range: 2 to 50,000 mW / sqm
UV Proportion Range: 8 to 10,000 mW / Lumen
RH Sensor: Capacitive film type
RH Range: 0 to 100% RH
Display Resolution: Lux: 0.1 up to 100 then 1
Foot-candles: 0.1 up to 100 then 1
UV: 0.1 up to 100 then 1
Proportion of UV: 1 mW / Lumen
Temperature: 0.1°C or °F
RH: 0.1
Accuracy: Light and UV: 5% ± 1 displayed digit
Temperature: ±0.5°C (±0.9°F)
RH: ±2.5%
Angular Response:
(Light & UV)
Cosine
Readout: 8 line graphical Liquid Crystal Display with automatic backlight
Data Logging Time Intervals:
(Time Till Full)
10 seconds (30 hours), 1 minute (7½ days), 10 minutes (75 days), 1 hour (454 days)
Data Logging Storage Capacity: 10,900 readings of all 4 parameters
Storage Resolution for Logged Data: Light & UV: 0.1% of saved value
Temperature: 0.5°C
Humidity: 0.5% RH
Computer Interface: IrDA compatible wireless infrared link.
Date Function: Display as day-month-year or month-day-year.
Batteries: 2 alkaline AA type
Battery Life: Approx. 100 hours continuous use or 12,000 readings taking 30 seconds each. Battery life will be less if the display backlight is used
External Power Supply:
Unless specifically requested, the meter does NOT include a connection for an external supply.
4.0 to 5.2V DC, 100 mA A suitable mains power supply can be provided as an optional extra (please specify mains voltage required).
Operating Temperature: 32 to 122°F
0 to 50°C